TT-203 / CONTROLLED SYNTHETIC INSPECTION FIXTURE Report ID: TT-203-26C Client: North Ridge Fabrication Services Ltd. Inspection period: 2026-11-05 to 2026-11-07 Prepared by: A. Mercer Work order: WO-203-081 Scope: Pipe spool weld inspection, controlled synthetic records. No reviewer approval, material acceptance or release is issued. ULTRASONIC / MAGNETIC PARTICLE METHOD EXPORT Machine acquisition sequence is shuffled. The same joint can appear in the VT/PT log and here. For UT-10 depth the operator lists 2.8 mm and the independent logger 4.1 mm. Neither is signed as final. DO NOT enter either depth. Inspection ID | Joint ID | Method | Date | Inspector | Result / finding | Indication | Location | Length mm | Depth mm | Code | Review note | Disposition | Reinspection? | Source INSP-203-10 | WJ-203-10 | UT | 2026-11-05 | I-22 | Indication unresolved: inconsistent depth | UT-10 | At 11 oclock | 20.0 | | UT-PROC-11 | Operator depth 2.8 mm; logger 4.1 mm; no signed reconciliation | OPEN | YES | UT-010 INSP-203-13 | WJ-203-03 | MT | 2026-11-06 | I-33 | No reportable indication | NONE | Cap and toes | | | MT-PROC-02 | Separate inspection method | RECORDED | NO | MT-013 INSP-203-04 | WJ-203-04 | UT | 2026-11-05 | I-22 | Linear indication reported | UT-04 | Root at 4 oclock | 24.0 | 3.2 | UT-PROC-11 | Repair plan requested, not final acceptance | OPEN | YES | UT-004 INSP-203-08 | WJ-203-08 | UT | 2026-11-05 | I-22 | No recordable indication | NONE | Full scanned length | | | UT-PROC-11 | Machine log clear for this scan | RECORDED | NO | UT-008 INSP-203-11 | WJ-203-01 | UT | 2026-11-06 | I-22 | No recordable indication | NONE | Full scanned length | | | UT-PROC-11 | Second method on same joint; not another weld | RECORDED | NO | UT-011 INSP-203-05 | WJ-203-05 | MT | 2026-11-05 | I-33 | Rounded surface indication | MT-05 | Cap at 7 oclock | 6.0 | | MT-PROC-02 | Technical disposition pending | OPEN | YES | MT-005 INSP-203-12 | WJ-203-02 | UT | 2026-11-06 | I-22 | No recordable indication | NONE | Full scanned length | | | UT-PROC-11 | Does not supersede VT undercut finding | RECORDED | NO | UT-012 Instrument logger side record: UT-10 / INSP-203-10 / WJ-203-10 / observed depth 4.1 mm. Original operator side record: 2.8 mm. Discrepancy OPEN.