TT-203 / CONTROLLED SYNTHETIC INSPECTION FIXTURE Report ID: TT-203-26C Client: North Ridge Fabrication Services Ltd. Inspection period: 2026-11-05 to 2026-11-07 Prepared by: A. Mercer Work order: WO-203-081 Scope: Pipe spool weld inspection, controlled synthetic records. No reviewer approval, material acceptance or release is issued. VISUAL AND LIQUID PENETRANT LOG — INDEPENDENT TEST RECORDS Each inspection has its own inspection ID. Acquisition order is intentionally different from Excel row order. An inspection result is an observation, not an engineering acceptance or sign-off. Inspection ID | Joint ID | Method | Date | Inspector | Result / finding | Indication | Location | Length mm | Depth mm | Code | Review note | Disposition | Reinspection? | Source INSP-203-16 | WJ-203-07 | VT | 2026-11-06 | I-12 | No visible surface indication | NONE | Entire weld | | | VT-PLAN-04 | Does not resolve PT-07 finding | RECORDED | NO | VT-016 INSP-203-01 | WJ-203-01 | VT | 2026-11-05 | I-12 | No visible surface indication | NONE | Entire weld | | | VT-PLAN-04 | Visual inspection completed | RECORDED | NO | VT-001 INSP-203-09 | WJ-203-09 | PT | 2026-11-05 | I-34 | No reportable indication | NONE | Entire weld | | | PT-PROC-08 | Observed result only, no QA signature | RECORDED | NO | PT-009 INSP-203-07 | WJ-203-07 | PT | 2026-11-05 | I-34 | Linear surface indication | PT-07 | Toe at 9 oclock | 12.0 | | PT-PROC-08 | Reinspection requested | OPEN | YES | PT-007 INSP-203-03 | WJ-203-03 | VT | 2026-11-05 | I-12 | No visible surface indication | NONE | Entire weld | | | VT-PLAN-04 | Visual inspection completed | RECORDED | NO | VT-003 INSP-203-17 | WJ-203-08 | VT | 2026-11-06 | I-12 | No visible surface indication | NONE | Entire weld | | | VT-PLAN-04 | Separate method on same joint | RECORDED | NO | VT-017 INSP-203-15 | WJ-203-05 | VT | 2026-11-06 | I-12 | Visual inspection completed | NONE | Entire weld | | | VT-PLAN-04 | Original MT-05 finding remains in history | RECORDED | NO | VT-015 INSP-203-06 | WJ-203-06 | VT | 2026-11-05 | I-12 | No visible surface indication | NONE | Entire weld | | | VT-PLAN-04 | No acceptance authorization in notes | RECORDED | NO | VT-006 INSP-203-18 | WJ-203-09 | VT | 2026-11-06 | I-12 | No visible surface indication | NONE | Entire weld | | | VT-PLAN-04 | Separate method on same joint | RECORDED | NO | VT-018 INSP-203-14 | WJ-203-04 | VT | 2026-11-06 | I-12 | Visible weld surface inspected | NONE | Cap and toes | | | VT-PLAN-04 | Original UT-04 finding remains in history | RECORDED | NO | VT-014 INSP-203-02 | WJ-203-02 | VT | 2026-11-05 | I-12 | Undercut observed | UC-02 | Toe at 2 oclock | 18.0 | 1.0 | VT-PLAN-04 | Hold for engineering evaluation | OPEN | YES | VT-002 INSP-203-02 VT undercut stays OPEN despite a later UT no-indication record on the same joint. Do not reinterpret a different method as a signed correction.