TT-203 / CONTROLLED SYNTHETIC INSPECTION FIXTURE Report ID: TT-203-26C Client: North Ridge Fabrication Services Ltd. Inspection period: 2026-11-05 to 2026-11-07 Prepared by: A. Mercer Work order: WO-203-081 Scope: Pipe spool weld inspection, controlled synthetic records. No reviewer approval, material acceptance or release is issued. REPAIR AND FOLLOW-UP HISTORY — NO IMPLIED FINAL RELEASE A follow-up result belongs to the specific repair and inspection ID. Original findings must not be overwritten. REPT-203-03 repeat penetrant report was requested but has NO measured final result in the supplied record. Repair ID | Joint ID | Original inspection | Defect ref | Repair action | Repair date | Repair WPS | Repair welder | Follow-up ID | Follow-up method | Follow-up result | Source / authority | Disposition | Closed by | Closure date REP-203-03 | WJ-203-07 | INSP-203-07 | PT-07 | Local toe repair documented | 2026-11-06 | WPS-09 Rev 2 | WL-20 | REPT-203-03 | PT | | RPR-03 / FU-03 | FOLLOW-UP PENDING | | REP-203-01 | WJ-203-04 | INSP-203-04 | UT-04 | Localized excavation and weld repair | 2026-11-06 | WPS-07 Rev 3 | WL-18 | REUT-203-01 | UT | No recordable indication | RPR-01 / FU-01 | REINSPECTED | | REP-203-04 | WJ-203-02 | INSP-203-02 | UC-02 | Repair planned but not performed | | | | | | | RPR-04 | OPEN | | REP-203-02 | WJ-203-05 | INSP-203-05 | MT-05 | Blend and local surface repair | 2026-11-06 | WPS-09 Rev 2 | WL-19 | REMT-203-02 | MT | No reportable indication | RPR-02 / FU-02 | REINSPECTED | | REINSPECTED is a historical step, not an automatic material acceptance. Closed by and Closure date remain blank for every repair.