LAB-301 / TENSILE FRAME OUTPUT — INDEPENDENT MACHINE LOG
Test date: 2026-11-05
Machine: UTM-44
Operator: R. Singh
Output columns: specimen, diameter mm, yield force kN, max force kN, initial gauge mm, final gauge mm.
Values are shuffled by file export sequence. Do not associate by line order.

Specimen ID | Lot ID | Heat ID | Diameter mm | Yield force kN | Max force kN | Initial gauge mm | Final gauge mm | Machine record | Technician note
T-406 | LOT-B62 | HEAT-8M14 | 12.50 | 74.2 | 91.3 | 50.0 | 57.2 | E8-406 | signed correction changes max force from 91.3 to 89.3 kN only
T-401 | LOT-A47 | HEAT-7K21 | 12.50 | 64.0 | 91.6 | 50.0 | 58.4 | E8-401 | routine
T-408 | LOT-D28 | HEAT-4P33 | 12.50 | 41.2 | 60.1 | 50.0 | 64.4 | E8-408 | routine
T-404 | LOT-C31 | HEAT-3T09 | 12.50 | 36.5 | 45.2 | 50.0 | ILLEGIBLE / NO VERIFIED VALUE | E8-404 | final gauge illegible, withhold elongation
T-403 | LOT-A47 | HEAT-7K21 | 12.50 | 63.2 | 90.9 | 50.0 | 57.6 | E8-403 | routine
T-407 | LOT-C31 | HEAT-3T09 | 12.50 | 35.8 | 44.5 | 50.0 | 56.6 | E8-407 | routine
T-402 | LOT-B62 | HEAT-8M14 | 12.50 | 75.0 | 105.5 | 50.0 | 56.8 | E8-402 | routine
T-405 | LOT-D28 | HEAT-4P33 | 12.50 | 40.5 | 59.3 | 50.0 | 65.2 | E8-405 | routine

WARNING: T-404 has no verified final gauge length. Do not infer elongation from another specimen.
Issue A contains T-406 max force 91.3 kN. A separately signed amendment may supersede ONLY that field.